Quick Specs & Benefits View flow rate, performance and product specifications
  • Brand: DAB
  • Model: DAB-JETCOM82NXT
  • Made In: Italy
  • Flow Rate: 60 L/min
  • Maximum Simultaneous Taps: 4
  • kW: 0.6
  • Electrical Connection Type: Single phase, 220-240 V ~, 50 Hz
  • LCD/LED Status Indicator: Yes
  • Minimum/Maximum Pressure: 461 kPa
  • WiFi Controller Built In or Compatible: No
  • Warranty: 2 Years
  • Width: 170 mm
  • Height: 198 mm
Recommended

Silver Package

2 of 3
From ...

Select Your Preferred Install

Choose an exact installation date, or stay flexible and save.
DAB PRESSURE PUMP SUPPLY & INSTALLATION

DAB JETCOM82NXT Pressure Pump Installation Brisbane & Gold Coast

JR Gas & Water supplies and professionally installs the DAB JETCOM82NXT pressure system across Brisbane, the Gold Coast and surrounding South East Queensland service areas.

The Australian JETCOM82NXT package combines DAB's JetCom 82 self-priming technopolymer surface pump with a Bianco NXT Core digital pump controller. It is designed for clean-water applications where automatic pressure control, dependable household water supply, tank-water use, water transfer or garden supply is required.

With a listed maximum flow of 60 litres per minute and maximum head of 47 metres, the JETCOM82NXT sits in the domestic pressure-pump category and can suit both straightforward pump replacement and new pressure-pump installations where the water source, suction conditions, plumbing and electrical supply are appropriate.

JR services Brisbane, the Gold Coast, Logan, Ipswich, Redlands, Moreton Bay and surrounding eligible South East Queensland areas.

DAB JETCOM82NXT quick answer: the JETCOM82NXT is a self-priming surface-mounted clean-water pressure system using a DAB JetCom 82 pump and Bianco NXT Core controller. It provides up to 60L/min flow and up to 47m head, with automatic start on pressure drop, stop on no flow, dry-run protection and automatic restart. The pump has 1-inch inlet and outlet connections and is backed by a 24-month manufacturer warranty, subject to current warranty conditions.

DAB JETCOM82NXT Supply & Installation at a Glance

Maximum Flow

60 L/min

Published maximum flow for the Australian JETCOM82NXT pressure-system package.

Maximum Head

47 m

Maximum pump head; actual available flow reduces as total system head increases.

Controller

Bianco NXT Core digital pressure controller with automatic operation and pump-protection functions.

Installation Type

Exact replacement, replacement requiring pipework changes or complete new pressure-pump installation.

Who Is the DAB JETCOM82NXT Best For?

Tank-Water Homes

Suitable where a surface pump is required to draw clean water from a rainwater tank, storage tank or similar source and automatically pressurise the connected plumbing.

Domestic Pressure Supply

Useful for normal household and property pressure duties where the required flow and head fall within the JetCom 82 performance range.

Existing Pump Replacement

A practical replacement option where an older surface pressure pump has failed and the existing water source, pipework, position and electrical supply suit the JETCOM82NXT.

PRODUCT SUITABILITY

Is the DAB JETCOM82NXT Right for My Property?

A Good Choice If...

You need an automatic surface-mounted pressure system for a suitable clean-water source and your expected pressure and flow demand fall within the JetCom 82 operating range.

Consider Another Pump If...

Your site needs substantially higher flow, variable-speed constant-pressure control, a submersible in-tank pump, dirty-water handling or specialised bore-pump performance.

JR Should Check First If...

The pump has a long suction run, significant suction lift, unusually small pipework, high simultaneous demand, uncertain power supply or a non-standard water-source arrangement.

DAB JETCOM82NXT Size & Installation Space

The underlying JetCom 82 pump is a compact horizontal surface-mounted unit. Published DAB dimensions for the pump body are approximately 406mm long, 170mm wide and 198mm high before allowing for the NXT controller, pipework, valves and practical servicing space.

Pump Length

406 mm

Pump Width

170 mm

Pump Height

198 mm

These are pump-body dimensions. The complete installed pressure system requires additional clearance for the controller, inlet and outlet pipework, valves, electrical connection, priming access and future servicing.

How Does the DAB JETCOM82NXT Work?

Water source: the JetCom 82 draws clean water through its suction inlet from a suitable tank, well or other compatible source.

Self-priming jet pump: the centrifugal jet arrangement provides the suction capability and pressure needed to move water into the property's delivery pipework.

NXT Core controller: the digital controller monitors system pressure and flow.

Automatic start: when an outlet opens and pressure falls below the controller's start setting, the pump starts automatically.

Automatic stop: when water demand ends and flow stops, the controller shuts the pump down.

What Does the NXT Core Controller Do?

The Australian JETCOM82NXT package includes the Bianco NXT Core digital pressure controller rather than operating the JetCom pump as a basic standalone transfer pump.

Automatic Pressure Control

The controller starts the pump when system pressure falls and stops the pump once water flow ends.

Dry-Run Protection

The NXT Core includes dry-run protection and an automatic restart function designed to recheck water availability after a loss-of-water event.

Frequent-Start Protection

Protection functions help manage abnormal rapid cycling rather than simply allowing the pump to repeatedly start without intervention.

Adjustable Start Pressure

The controller's cut-in pressure can be adjusted from its normal default setting to suit an appropriate installation.

IP65 Controller

The NXT Core controller carries an IP65 enclosure rating, subject to correct installation and connection.

Integrated Accumulator

The Core controller incorporates a small fixed accumulator as part of the pressure-control package.

Key DAB JETCOM82NXT Features

Self-Priming Jet Design

DAB's JetCom range is designed for good priming capability and can handle small amounts of air within the water during suitable clean-water applications.

Technopolymer Pump Body

The JetCom variant uses a technopolymer pump body rather than the cast-iron body used on DAB's standard Jet series.

60 L/min Maximum Flow

Provides a useful domestic flow range for appropriately sized household, tank-water and garden applications.

47m Maximum Head

Suitable for pressure duties where the required operating point falls within the JetCom 82 performance curve.

Drinking-Water Approval

The Australian JETCOM82NXT package is listed as approved for drinking-water contact under the applicable product approval.

Automatic Pump Protection

The NXT controller adds dry-run, restart and frequent-start protection to the pressure system.

DAB JETCOM82NXT Specifications

Specification DAB JETCOM82NXT
Brand DAB Pumps
Australian Package Model DAB-JETCOM82NXT
Australian Order Code 808409
Pump DAB JetCom 82 self-priming centrifugal pump
Controller Bianco NXT Core digital pressure controller
Suitable Liquid Clean water
Maximum Flow 60 L/min
Maximum Head 47m
Nominal Motor Output P2 0.6kW / 0.8HP
Maximum Pump Input P1 Approximately 0.85kW
Electrical Supply Single phase, 220–240V, 50Hz
Pump Current Approximately 3.8A
Pump Inlet 1" BSP female
Pump / System Outlet 1" BSP connection arrangement
Pump Body Technopolymer
Pump Installation Fixed horizontal surface-mounted installation
Pump Protection Class IP44 motor enclosure
Controller Protection Class IP65
Controller Maximum Current 10A
Controller Maximum Rated Power 1.5kW
Controller Start Pressure 2.2 bar default, adjustable
Controller Stop Function Stops on no flow
Dry-Run Protection Yes, with automatic restart function
Liquid Temperature 0°C to 35°C for normal domestic JetCom applications
Maximum Ambient Temperature 40°C
Maximum Pump Operating Pressure 6 bar / 600kPa
Pump Length Approximately 406mm
Pump Width Approximately 170mm
Pump Height Approximately 198mm
Manufacturer Warranty 24 months, subject to current manufacturer warranty conditions

The commonly used “0.6kW” JETCOM82NXT description refers to the JetCom 82's nominal motor output. DAB's technical data separately identifies a higher electrical input figure. Maximum flow and maximum head also occur at different points on the pump curve and should not be expected simultaneously.

Understanding the 60 L/min & 47m Ratings

A maximum-flow figure does not mean the pump will deliver 60 litres per minute at every property.

Pump performance changes with total head. As the pump is required to work against greater elevation, pressure and pipe resistance, the available flow reduces.

Pipe diameter, suction lift, horizontal pipe length, filters, valves, bends, fittings and the number of outlets operating at the same time all affect the real operating point.

Size the pump by actual demand. Do not choose a pump only from the maximum litres-per-minute figure or a generic “number of taps” rating. Required flow and pressure at the property should be considered together.
INSTALLATION REQUIREMENTS

What Is Required to Install a DAB JETCOM82NXT?

Suitable clean-water source
Correctly sized suction pipework
Airtight suction-side connections
Suitable non-return or foot-valve arrangement where required
Correctly sized delivery pipework
Appropriate isolation valves
Firm and stable pump base
Suitable weather-protected location
Access for priming
Suitable electrical supply
Access to controller and connections
Commissioning after installation

A pressure pump should be installed as part of the complete hydraulic system. Correct pump selection alone cannot compensate for unsuitable suction pipework, air leaks, excessive restrictions or poor installation conditions.

Self-Priming Pump & Suction Conditions

DAB's JetCom range uses a self-priming centrifugal jet design intended for applications where strong suction capability is useful.

This makes the JETCOM82NXT suitable for many tank and suitable well-water arrangements where a surface pump needs to draw water into the pump before delivering pressure downstream.

Self-priming does not remove the need for correctly designed suction plumbing. Air leaks, long suction lines, excessive vertical lift, blocked foot valves and undersized pipes can still cause poor performance or repeated loss of prime.

JR should assess the complete suction arrangement where the pump is not mounted close to the water source or where the source water level is substantially below the pump.

Priming the DAB JETCOM82NXT

A surface-mounted self-priming pump still needs to be initially filled and commissioned correctly before normal operation.

Priming establishes water in the pump casing and suction arrangement so the pump can develop the suction required to draw from the source.

Where the system repeatedly loses prime, simply refilling and restarting the pump is not a complete repair. The suction pipe, foot valve or non-return valve, fittings and source-water conditions should be checked for the cause.

Pump Location & Weather Protection

The JETCOM82NXT is a surface-mounted pressure system and should be positioned on a stable base where the pump and controller remain accessible.

The installation location needs to consider drainage, ventilation around the air-cooled motor, exposure to weather, electrical safety, pipe support and service access.

The NXT controller carries an IP65 rating, but that does not mean the complete pump system should be placed in an unsuitable flooded or poorly protected location.

Future access to the controller, priming point, valves and pump should be preserved rather than boxing the system into an inaccessible enclosure.

Electrical Requirements

The JetCom 82 is a single-phase 220–240V, 50Hz pump. Current DAB technical data identifies approximately 0.85kW maximum electrical input, 0.6kW nominal motor output and around 3.8A running current.

The NXT Core controller is rated for single-phase pump loads up to 10A and 1.5kW, comfortably covering the JetCom 82 within the packaged system.

Existing power still needs to be suitable for the installed position. Changing from hard-wired to plug-in supply, relocating the pump or installing a completely new system can alter the electrical scope.

JR's live Gold installation pathway is designed for new installations requiring a broader plumbing and power setup.

JR DAB JETCOM82NXT Installation Packages

JR's current live selector separates JETCOM82NXT installation into three pathways according to what is already at the property.

Base — Essential Replacement

Intended for an exact replacement of an existing DAB JETCOM82NXT where the current installation remains suitable.

Existing pump removal
New JETCOM82NXT reinstatement
Electrical disconnect and reconnect
Existing suitable pipework retained

Silver — Replacement Plus

Intended for replacement of an existing pressure pump where plumbing alterations are required to suit the new JETCOM82NXT.

Existing pump removal
New pump installation
Electrical disconnect and reconnect
Pipework alterations within package scope

Gold — Complete New Installation

Intended for a brand-new pressure-pump installation requiring the broader connection, valve, plumbing and electrical pathway.

Brand-new pump installation
New power point within package scope
Full valve and connection set
Required pipework upgrades within package scope

Current package inclusions, installation timeframes and pricing are controlled by JR's live selector above. Use the live package description as the final booking reference.

What's Included With DAB JETCOM82NXT Installation?

Exact inclusions depend on the package selected, but an applicable JR installation pathway can include:

DAB JETCOM82NXT pressure system
Bianco NXT Core controller
Existing pump removal where applicable
Positioning and mounting of new pump
Connection to suitable suction pipework
Connection to suitable delivery pipework
Electrical work according to selected package
Pump priming
Controller setup
Leak checking
Operational commissioning
Basic customer handover

What May Require Additional Work?

Major suction-line replacement or rerouting
Rectification of air leaks in existing buried pipework
Major delivery-pipe upgrades
Tank repairs or structural tank modifications
Pump relocation outside selected package scope
Major electrical upgrades outside selected package
Structural pump bases or major construction work
Specialist filtration or water-treatment equipment
Complex mains-pressure redesign
Rectification of unrelated plumbing defects

Non-standard pipework, access problems, unusual water sources and electrical changes may need to be assessed before the final installation scope can be confirmed.

How Much Does DAB JETCOM82NXT Installation Cost?

Current supplied-and-installed pricing is shown through JR's live package selector above rather than being hardcoded into this product description.

The final installation pathway depends on whether the job is an exact JETCOM82NXT replacement, a replacement of another pump requiring pipework alterations or a completely new installation.

Suction conditions, existing valves, pipe sizes, electrical supply, pump location, access and any required upgrades can also affect the installation scope.

BRISBANE INSTALLATION

DAB JETCOM82NXT Installation Brisbane

JR Gas & Water supplies and installs DAB JETCOM82NXT pressure systems throughout Greater Brisbane for suitable tank-water, household pressure, replacement-pump and clean-water applications.

Brisbane pump installations can range from straightforward replacement of an existing surface pump to complete new pressure systems requiring new valves, pipework or electrical connections.

JR considers the water source, suction arrangement, required pressure and flow, pipe sizing, pump location, power supply and future service access before confirming the installation pathway.

JR also services Logan, Ipswich, Redlands and Moreton Bay, subject to current service-area and installation availability.

GOLD COAST INSTALLATION

DAB JETCOM82NXT Installation Gold Coast

JR Gas & Water provides DAB JETCOM82NXT supply, replacement and installation across eligible Gold Coast service areas.

Existing tank and pressure-pump installations can vary significantly in suction length, water-source level, pipe diameter, valve arrangement and electrical setup.

JR assesses whether the site suits a straightforward Base replacement, a Silver replacement requiring alterations or a Gold complete new installation before the final scope is confirmed.

Can the DAB JETCOM82NXT Replace My Existing Pump?

Replacing Another JETCOM82NXT

Usually the simplest installation pathway where the existing pump position, suction plumbing, delivery pipework and electrical supply remain suitable.

Replacing Another Surface Pump

Often possible, but inlet and outlet positions, pipe sizes, controller arrangement, valves and electrical connection need to be checked.

New Pressure-Pump Installation

Requires planning of the complete installation including water source, suction pipe, delivery pipe, valves, power, pump location and future maintenance access.

JETCOM82NXT vs a Basic Transfer Pump

JETCOM82NXT Pressure System

Combines a self-priming pressure pump with automatic pressure and flow control, allowing it to respond automatically when household or garden water demand begins.

Basic Transfer Pump

Primarily intended to move water between locations and may not include the automatic pressure control required for normal household pressure-system operation.

A basic transfer pump may be the more appropriate choice where the only goal is moving water between tanks. The JETCOM82NXT is intended for applications where automatic pressurised supply is required.

JETCOM82NXT vs a Submersible Tank Pump

JETCOM82NXT Surface Pump

Installed outside the tank, making the pump and controller readily accessible for inspection, priming and servicing.

Requires suitable suction pipework between the water source and pump.

Submersible Pump

Installed inside the tank and pushes water into the delivery pipe rather than relying on an external suction line.

Can reduce external pump equipment but requires adequate tank access for future pump removal.

The better installation type depends on the existing plumbing, tank access, pump location, noise preferences, service access and whether the current system is already surface mounted or submersible.

JETCOM82NXT vs Variable-Speed Pressure Systems

The NXT Core is an automatic on/off pressure controller. It starts the pump at a defined pressure and stops when flow ends.

A variable-speed pump system operates differently by adjusting motor speed to maintain a target pressure across changing flow demand.

The JETCOM82NXT can be a practical fit where conventional automatic pressure control suits the application. Properties needing more advanced constant-pressure performance or specialised boosting may require a different pump system.

Water Quality & Intended Use

The JetCom is designed for clean water rather than sewage, drainage water or liquids containing significant solids or abrasive material.

DAB identifies JetCom applications including residential pressurisation, rainwater reuse, gardening, irrigation and drawing water from suitable tanks, cisterns and wells.

Drinking-water product approval relates to the materials used in the pump and pressure-system package. It does not automatically make untreated rainwater or another source suitable for drinking.

Where water quality requires filtration or treatment, those components need to be selected separately according to the source and intended use.

COMMON QUESTIONS

DAB JETCOM82NXT Installation FAQs

What is the DAB JETCOM82NXT?

It is an Australian packaged pressure system combining a DAB JetCom 82 self-priming technopolymer pump with a Bianco NXT Core automatic digital pressure controller.

What is the maximum flow rate?

The current Australian JETCOM82NXT specification lists a maximum flow of 60 litres per minute. Actual flow depends on the total head and resistance in the installed system.

What is the maximum head?

The JetCom 82 is rated to approximately 47 metres maximum head. Maximum head and maximum flow occur at different points on the pump curve.

Is the JETCOM82NXT really a 0.6kW pump?

The model is commonly marketed as the 0.6kW version because 0.6kW is the nominal motor output. DAB's technical data separately lists approximately 0.85kW maximum electrical input.

What controller comes with the JETCOM82NXT?

The current Australian pressure-system package includes the Bianco NXT Core digital pump controller.

Does the pump start automatically?

Yes. The NXT Core controller starts the pump when pressure falls below its start setting and stops the pump when water flow ends.

Does the controller have dry-run protection?

Yes. Dry-run protection and automatic restart functionality are included in the NXT Core controller.

What is the controller's normal start pressure?

The NXT Core uses a 2.2 bar default cut-in setting, with adjustment available where appropriate for the installation.

Is the JETCOM82NXT self priming?

Yes. The underlying DAB JetCom pump is a self-priming centrifugal jet pump. Correct suction plumbing and initial commissioning are still required.

Can it draw water from a rainwater tank?

Yes. Drawing clean water from a suitable rainwater tank or storage source is a common application, provided the suction arrangement and hydraulic duty suit the pump.

Can it draw water from a well?

DAB identifies suitable well-water extraction among JetCom applications. Actual suitability depends on water level, suction lift, pipework and the required delivery pressure and flow.

Can it be used for garden irrigation?

Yes. DAB identifies gardening and irrigation as suitable JetCom applications where the required flow and pressure fall within the pump's performance range.

Can it supply a house?

It can be used for suitable domestic water-pressure applications. Household demand, simultaneous outlets, pipe sizing, elevation and source-water conditions need to be checked rather than relying only on the maximum-flow figure.

What size are the pipe connections?

The current Australian specification lists a 1-inch BSP female pump inlet and a 1-inch connection through the outlet/controller arrangement.

What power supply does it require?

The JetCom 82 pump is designed for single-phase 220–240V, 50Hz electrical supply.

Does it require priming?

Yes. As a surface-mounted pump, correct initial priming is required. Repeated loss of prime normally indicates a suction-side issue that should be investigated.

Can the JETCOM82NXT replace my current pump?

Often, yes. Compatibility depends on the water source, suction and discharge pipework, required pressure and flow, pump position and electrical arrangement.

What is included with an exact replacement?

JR's current Base installation pathway is intended for exact replacement of an existing JETCOM82NXT, including pump removal and reinstatement plus the applicable electrical disconnect and reconnect.

What if I am replacing a different pump?

JR's current Silver pathway is designed for replacement of an existing pump where pipework alterations are required to suit the JETCOM82NXT.

Can JR install one where there is no existing pump?

Yes. JR's current Gold pathway is intended for complete new installations and includes a broader valve, pipework and electrical scope.

What warranty does the DAB JETCOM82NXT have?

The current Australian product listing provides a 24-month DAB Pumps warranty, subject to current manufacturer terms and installation requirements.

Can JR install the JETCOM82NXT in Brisbane?

Yes. JR supplies and installs suitable pressure pumps throughout Greater Brisbane and surrounding eligible South East Queensland areas.

Can JR install the JETCOM82NXT on the Gold Coast?

Yes. JR provides suitable pressure-pump installation across eligible Gold Coast service areas.

How much does DAB JETCOM82NXT installation cost?

Current supplied-and-installed pricing is displayed in JR's live package selector above. The final installation pathway depends on whether the job is an exact replacement, altered replacement or complete new installation.

DAB JETCOM82NXT Warranty & Maintenance

24-Month Manufacturer Warranty

The current Australian JETCOM82NXT listing includes a two-year DAB Pumps warranty, subject to the manufacturer's current warranty terms.

Keep the Suction Side Airtight

Suction leaks, damaged valves, blocked strainers or loss of prime can cause poor pump performance even when the pump and controller remain serviceable.

Maintain Service Access

Keep the pump, NXT controller, valves, priming point and electrical connection accessible for inspection and future servicing.

DAB's product warranty is separate from JR's installation workmanship and support terms. Refer to the current JR installation package and warranty terms for the coverage applying to the selected job.

Why Choose JR Gas & Water for JETCOM82NXT Installation?

LICENSED

Plumbing and associated installation work completed through appropriately licensed tradespeople.

3 PATHS

Defined Base, Silver and Gold pathways for exact replacement, altered replacement and complete new installation.

SYSTEM CHECK

Water source, suction conditions, pipework, required pressure, electrical supply and service access considered together.

SEQ

Brisbane, Gold Coast and surrounding South East Queensland service coverage.

A pressure pump needs to suit the entire property water system, not just the space left by the old pump. JR considers the source of water, suction layout, pressure and flow demand, pipe sizing, controller setup, electrical supply and future maintenance access before completing the installation pathway.

COMPARE YOUR OPTIONS

Compare Water Pump Options

Compare the DAB JETCOM82NXT with JR's wider live water-pump range if your property needs a different flow rate, more pressure, a submersible system, automatic rain-to-mains control or a variable-speed pressure system.

READY TO INSTALL

Install the DAB JETCOM82NXT With JR Gas & Water

The DAB JETCOM82NXT is a practical automatic surface-mounted pressure system for suitable homes and properties requiring clean-water pressure from a tank, well or compatible stored-water source.

Before installation, confirm the water source, suction arrangement, required pressure and flow, pipe sizes, pump location, electrical supply and whether the job is an exact replacement, altered replacement or complete new installation.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.