What is the Davey KRB1?
The KRB1 is a surface-mounted Davey RainBank system combining an HP45-05
pump, RainBank automatic rain-to-mains controller and top-entry tank float
switch.
What flow rate does the KRB1 provide?
Davey rates the KRB1 complete system at 40 litres per minute at 200kPa.
Actual fixture performance depends on the pipework, elevation and total
system resistance.
Is the KRB1 suitable for a single-storey house?
Yes. Davey's selection guide places the KRB1 among the RainBank systems
providing adequate pressure for most normal single-storey buildings.
What pump does the KRB1 use?
The standard KRB1 uses Davey's HP45-05 surface-mounted horizontal
multistage pump.
How powerful is the HP45-05 pump?
Davey's current technical data lists 0.77kW input power, 0.55kW output
power and a 3.4A full-load current.
Does the pump sit inside the tank?
No. The KRB1 uses a surface-mounted pump outside the tank. The KRBS1 is the
comparable Davey RainBank model using an in-tank submersible pump.
Does the KRB1 use a float switch?
Yes. The standard KRB1 uses a top-entry tank float switch. Davey's current
data lists a 9m lead for the top-entry float arrangement.
What is the difference between KRB1 and KRB1NF?
KRB1 uses an external tank float switch to detect rainwater availability.
KRB1NF is Davey's floatless surface-pump version and is intended for suitable
flooded-suction installations.
Does the KRB1 automatically switch to mains water?
Yes. RainBank gives rainwater priority and automatically provides mains
backup when usable tank water is unavailable.
What happens when the rainwater tank is empty?
RainBank changes the connected rainwater outlets to mains-water backup so
normal supply can continue.
What happens during a power outage?
Davey states that RainBank maintains mains-water backup during an electrical
interruption. The surface pump itself cannot deliver rainwater without
electricity.
Can the KRB1 supply toilets and laundry?
Yes. These are among the normal domestic applications Davey identifies for
RainBank systems where the complete installation is appropriately sized.
Can the KRB1 supply garden taps?
RainBank can also supply suitable exterior outlets. Simultaneous household
demand still needs to remain appropriate for the KRB1's performance.
Can the KRB1 be used for irrigation?
Davey includes irrigation among RainBank applications, but larger irrigation
flow requirements may justify a higher-output pump system.
Does RainBank include backflow protection?
The RainBank controller incorporates a dual-check backflow valve. The
complete property installation must still meet the applicable plumbing and
backflow requirements.
Can the KRB1 replace my existing RainBank system?
Often, yes. Suitability depends on the tank, pump location, float switch,
suction pipework, delivery pipework, mains backup and electrical supply.
Can it replace another surface-mounted pump?
Potentially. The KRB1 also introduces RainBank source switching and a tank
float arrangement, so pipework and controls may need modification when
replacing a basic pump-only system.
Can the KRB1 draw water from below the pump?
The HP pump family can support suitable suction-lift installations, but
reliable operation depends on the complete suction arrangement, priming,
pipe sizing and water level. Davey's pump data lists a maximum suction head
of 6m for the HP pump family.
Does the KRB1 require priming?
Yes. A surface-mounted pump needs to be correctly primed where required by
the installation arrangement. Repeated loss of prime should be investigated
rather than simply restarting the pump.
What warranty does the Davey KRB1 have?
Davey's current Australian RainBank information lists a 36-month
manufacturer warranty, subject to the current warranty conditions and
installation requirements.
Can JR install the KRB1 in Brisbane?
Yes. JR provides suitable RainBank and pump installation throughout Greater
Brisbane and surrounding eligible South East Queensland areas.
Can JR install the KRB1 on the Gold Coast?
Yes. JR provides suitable Davey pump and RainBank installation across
eligible Gold Coast service areas.
How much does Davey KRB1 installation cost?
Current supplied-and-installed pricing is shown in JR's live installation
selector above. Final scope depends on whether the job is a straightforward
replacement or requires plumbing, float-switch, backflow, pump-base or
electrical changes.