Your Saved Filtration Setup
Review Your Selected Systems
Cart Progress Checking...
Award Winning
2023–2025 ProductReview.com.au Winners
Product Protection
Live Availability
Same Day Installation Available 365 Days
Trusted Locally
1000+ 5-Star Google Installation Reviews

Puretec G6 Whole House UV Twin Filter System | Supply+Install | LIFETIME WARRANTY

Quick Specs & Benefits See what this filter targets and how it helps
  • Quality Category: Premium
  • Warranty: Comprehensive 3 Year
  • NSF/ANSI Certified: Yes
What This Filter Helps With
Sediment & Visible Particles The product data lists particles such as dirt, sand, silt, rust or sediment. The particulate stage helps capture these suspended solids before they travel through taps and appliances.
Chlorine, Taste & Odour This model is listed to help reduce chlorine and/or related taste and odour concerns, helping improve the everyday taste and smell of water throughout the home.
VOCs, Pesticides & Other Organic Chemicals The product data lists reduction of one or more organic chemical groups such as VOCs, pesticides, herbicides, solvents or pharmaceuticals. Exact performance depends on the filter media and the individual contaminant.
Listed Metals One or more metals such as lead, mercury, copper, arsenic or chromium are included in this model's contaminant data. Refer to the product certification or specification for the exact reduction claim for each metal.
Cysts / Microbiological Contaminants This model's data lists one or more cysts or microorganisms for reduction. This does not automatically mean the system disinfects water unless UV or another disinfection stage is specifically stated for the product.
View the full contaminant list for this model
Dirt, Sand, Silt, Rust, Sediment, Microplastics, Chlorine, Chloramine (partial reduction), Volatile Organic Compounds (VOCs), Pesticides, Herbicides, Industrial Solvents, Some Pharmaceuticals, Chlorine taste & odor, Organic smells, Sulfur compounds (reducing rotten egg smell), Lead (significant reduction), Mercury (significant reduction), Copper (significant reduction), Some arsenic compounds (partial reduction), Chromium 6 (partial reduction), Trihalomethanes (THMs), Haloacetic acids (HAAs), , E. coli, Salmonella, Campylobacter, Hepatitis A, Norovirus, Rotavirus, Giardia, Cryptosporidium, Algae, Fungal Spores, Microbial Cysts, Coliform Bacteria, and Legionella
"Helps reduce" or "removes" should be read according to the manufacturer's tested specification for the selected model and cartridge. Reduction does not necessarily mean 100% removal.
Recommended

Silver Package

2 of 6
From ...
GET A QUOTE ON THIS PACKAGE
Live Installation Checker
PURETEC WHOLE-HOUSE RAINWATER + UV FILTRATION

Puretec HYBRID-G6 Installation Brisbane & Gold Coast

JR Gas & Water supplies and installs the Puretec HYBRID-G6 whole-house rainwater filtration and UV system across eligible Brisbane, Gold Coast and surrounding South East Queensland service areas.

The current Puretec HYBRID-G6-LF is a compact dual-stage whole-house filtration system combined with ultraviolet treatment. Puretec designs the G6 primarily for homes using rainwater while also listing it as suitable for mains water applications where the overall installation and treatment requirements are appropriate.

The system uses a 5-micron washable pleated sediment cartridge followed by a 10-micron dual-purpose carbon cartridge before water enters the RL6 ultraviolet reactor. This allows the G6 to combine sediment reduction, carbon treatment and microbiological UV treatment in one weather-protected outdoor package.

Puretec HYBRID-G6 at a glance: HYBRID-G6-LF, dual 10-inch filtration, PL05MP1 5-micron washable sediment cartridge, DP10MP1 10-micron dual-purpose carbon cartridge, RL6 46W UV lamp, RQS6 quartz sleeve, 75 L/min published filtration rating, 54 L/min UV flow at 40mJ/cm², 70 L/min at 30mJ/cm², 130 L/min at 16mJ/cm², 1" BSP / 25mm connection, 300–875kPa supply-pressure range, 0–52°C water temperature and current 3-year Puretec warranty.

Puretec HYBRID-G6 Supply & Installation at a Glance

Dual-Stage Filtration

A 5-micron sediment cartridge is followed by a dual-purpose carbon cartridge before the water reaches the UV chamber.

Ultraviolet Treatment

The RL6 ultraviolet system provides a chemical-free treatment stage targeting microorganisms including E. coli, Giardia and Cryptosporidium cysts.

70 L/min @ 30mJ/cm²

Puretec identifies 30mJ/cm² as the industry-standard UV dose for drinking-water applications.

Outdoor Enclosure

The G6 includes a weather-protection cover, corrosion-resistant construction and lockable lid for suitable outdoor installations.

What Is the Puretec HYBRID-G6?

The Puretec HYBRID-G6 is an integrated rainwater treatment system combining two filtration stages with ultraviolet treatment.

It is installed on the incoming water line so treated water can be distributed throughout the home rather than only through a single drinking-water outlet.

The G6 first removes sediment and provides carbon treatment, then passes the filtered water through a UV chamber for microbiological treatment.

Its dual 10-inch cartridge format makes it a more compact option than Puretec's larger 20-inch Hybrid systems.

How Does the Puretec HYBRID-G6 Treat Water?

Stage 1 – PL05MP1

The first stage uses the PL05MP1 5-micron pleated sediment cartridge. It is washable and is designed to reduce silt, sludge, dirt, rust and suspended particulate material.

Stage 2 – DP10MP1

The second stage uses the DP10MP1 10-micron dual-purpose carbon cartridge. It provides additional particulate treatment together with carbon treatment for bad taste, odour and selected chemicals.

Final UV stage: Water then passes through the RL6 ultraviolet reactor. Effective UV treatment depends on correct flow rate, sufficient water clarity, lamp output, quartz-sleeve condition and proper servicing.

Why Choose the Puretec HYBRID-G6?

Filtration + UV in One Unit

The G6 combines sediment filtration, carbon treatment and UV treatment in one integrated whole-house package.

Compact 10-Inch Format

The dual 10-inch filter configuration is suited to homes that do not require the larger filtration capacity of Puretec's 20-inch systems.

Designed for Rainwater

Puretec specifically positions the G6 for residential rainwater treatment while also supporting suitable mains-water applications.

Outdoor Protection

The weather enclosure protects the filtration and UV components in appropriately selected external locations.

Lockable Lid

An anti-tamper and child-resistant lockable lid helps restrict unintended access to the system.

UV Monitoring

The controller includes a lamp countdown timer and audible and visible failure warnings.

PRODUCT SUITABILITY

Is the Puretec HYBRID-G6 Right for Your Home?

A Strong Fit If...

You use rainwater through the home and want sediment, carbon and microbiological treatment in one integrated package.

Ideal for Smaller Demand

The compact 10-inch filter format suits small to medium residential applications where the required flow remains within the complete system's hydraulic capacity.

Assessment May Be Needed If...

Your water is heavily stained, unusually turbid or contains elevated iron, manganese or hardness that could affect UV transmission or quartz-sleeve condition.

Rainwater and Mains Water Applications

Puretec designs the HYBRID-G6 primarily for rainwater supply.

The manufacturer also states that the Hybrid system is designed for mains and rainwater supply.

This can make the G6 suitable for rainwater-fed homes as well as properties where treated town water is used as part of the overall supply arrangement.

The final installation still needs to account for tank configuration, rainwater pump, mains/rainwater changeover equipment, pressure and the property's actual water quality.

Puretec HYBRID-G6 Specifications

Brand Puretec
Current Model HYBRID-G6-LF
Product Status Current Puretec listing
Product Type Dual-stage whole-house filtration + ultraviolet treatment
Primary Application Rainwater whole-house treatment
Additional Application Mains water where suitable
Filter Format Dual 10-inch filtration
Stage 1 Cartridge PL05MP1
Stage 1 5-micron washable pleated sediment filtration
Stage 2 Cartridge DP10MP1
Stage 2 10-micron dual-purpose carbon filtration
UV Lamp RL6
UV Lamp Power 46W
Quartz Sleeve RQS6
Published G6 Flow 75 L/min
UV Flow @ 40mJ/cm² 54 L/min
UV Flow @ 30mJ/cm² 70 L/min
UV Flow @ 16mJ/cm² 130 L/min
Connection 1" BSP / 25mm
Supply Pressure 300–875kPa*
Water Temperature 0–52°C, protect from freezing
Power Supply AC 240V / 50Hz
Outdoor Installation Weather-protected Hybrid G enclosure
UV Monitoring Lamp countdown timer + audible and visible failure warning
Maintenance Kit HR-G6R1
WaterMark WMTS103 certified Hybrid platform
Current Puretec Warranty 3 years
Warranty Structure 1 year parts and labour + 2 additional years parts only

*Where line pressure exceeds 500kPa, Puretec specifies that an approved pressure-limiting device must be installed in accordance with applicable Australian and New Zealand plumbing requirements.

Understanding the HYBRID-G6 Flow Ratings

The HYBRID-G6 has more than one published flow figure because filter flow and UV dose are different measurements.

Puretec promotes the G6 as a 75 L/min system, while its RL6 UV reactor has separate flow ratings according to the UV dose delivered.

UV Dose Published Maximum Flow Meaning
40mJ/cm² 54 L/min Higher UV dose at a lower maximum flow
30mJ/cm² 70 L/min Puretec identifies this as the industry-standard drinking-water UV dose
16mJ/cm² 130 L/min Lower UV dose at a higher maximum reactor flow

For a drinking-water application, the relevant Puretec UV benchmark is therefore 70 L/min at 30mJ/cm², rather than representing 130 L/min as the normal drinking-water UV flow.

Why UV Dose Matters

Ultraviolet treatment works by exposing microorganisms to UV energy while water passes through the reactor.

As flow increases, exposure time decreases. This is why Puretec publishes different maximum flow figures for different UV doses.

The complete system should therefore be sized around the required treatment dose and peak household demand rather than simply selecting the highest litres-per-minute figure shown in the UV table.

UV Treatment for E. coli, Giardia and Cryptosporidium

Puretec states that the HYBRID-G6 can provide treatment of up to 99.99% of E. coli, Giardia and Cryptosporidium cysts using its Radfire ultraviolet technology.

UV treatment uses light rather than chemical disinfectants.

Correct performance depends on the water being suitable for UV treatment, the system remaining within its flow limits and the lamp and quartz sleeve being maintained correctly.

Why Water Clarity Matters for UV

Puretec specifically states that Hybrid UV effectiveness depends on the clarity of the incoming water.

Particles, staining and other water-quality conditions can prevent ultraviolet light from passing efficiently through the water.

Where source-water clarity is uncertain, Puretec can arrange a UV transmission test to determine whether additional filtration is needed ahead of the UV chamber.

This is particularly relevant where rainwater contains unusually high sediment loading, iron, manganese or other contaminants.

Puretec Water-Quality Parameters for UV Treatment

Puretec's current Hybrid installation guide provides maximum recommended incoming-water parameters for correct UV operation.

Iron Less than 0.3 mg/L
Hydrogen Sulfide Less than 0.05 mg/L
Suspended Solids Less than 10 mg/L
Manganese Less than 0.05 mg/L
Hardness Less than 110 mg/L

Where these conditions are exceeded, additional treatment or more frequent quartz-sleeve maintenance may be required.

What Does the Puretec HYBRID-G6 Treat?

Silt
Sludge
Dirt
Rust
Sediment
Bad taste
Odour
Selected carbon-treatable chemicals
E. coli through UV treatment
Giardia through UV treatment
Cryptosporidium cysts through UV treatment

The HYBRID-G6 is not a reverse-osmosis system and is not designed to soften hard water or remove dissolved salts in the way those technologies do.

Outdoor Weather-Protected Design

The HYBRID-G6 incorporates a weather cover intended for suitable outdoor installations.

Puretec also specifies a lightweight high-strength aluminium bracket with protective coating, anti-corrosion construction and an anti-tamper, childproof lockable lid.

The hinged cover provides easier access to the UV lamp for scheduled servicing.

The system should still be protected from harsh environments involving excessive salt or aggressive chemicals and from freezing conditions.

UV Lamp Timer and Failure Warning

The G6 controller incorporates a lamp countdown timer together with audible and visible failure warnings.

This monitoring matters because a UV lamp may remain visibly illuminated while its germicidal UV output has declined with age.

Scheduled lamp replacement is therefore part of normal maintenance rather than waiting for the lamp to stop producing visible light.

Puretec HYBRID-G6 vs HYBRID-G7

Specification HYBRID-G6 HYBRID-G7
Filter Size 10 inch 20 inch
Stage 1 PL05MP1 PL05MP2
Stage 2 DP10MP1 DP10MP2
Published System Flow 75 L/min 130 L/min
UV Lamp RL6 RL6
UV Flow @ 30mJ/cm² 70 L/min 70 L/min
Connection 1" BSP 1" BSP
Main Difference Compact 10-inch filtration package Larger-capacity 20-inch filtration package

The G7 provides larger filter cartridges and greater filtration capacity, but both systems use the same RL6 UV platform. The G7 therefore does not increase the published 30mJ/cm² UV flow above the G6's 70 L/min figure.

Puretec HYBRID-G6 vs HYBRID-E7

Puretec currently promotes the newer HYBRID-E7 as an alternative where customers want additional capacity and Puretec's newer Hybrid enclosure platform.

The G6 remains listed as a current product, so this is not the same situation as the discontinued HYBRID-G12.

For a new installation, the better choice depends on required filtration capacity, installation space, household flow demand, budget and preferred enclosure design rather than automatically replacing the G6 with the newer model.

HYBRID-G6 Replacement Cartridges & UV Components

Stage 1 Replacement PL05MP1
Stage 2 Replacement DP10MP1
Replacement UV Lamp RL6
Replacement Quartz Sleeve RQS6
Complete Maintenance Kit HR-G6R1

The Puretec HR-G6R1 maintenance kit includes the PL05MP1 sediment cartridge, DP10MP1 taste-and-odour cartridge, RL6 UV lamp, RQS6 quartz sleeve, food-grade lubricant and replacement O-rings.

HYBRID-G6 Maintenance

Whole-house UV treatment requires ongoing servicing to maintain the treatment performance for which the system was designed.

Routine servicing includes filter-cartridge replacement, UV-lamp replacement and inspection or cleaning of the quartz sleeve.

Actual filter life depends on rainwater quality, sediment loading and household water usage.

The quartz sleeve may require more frequent cleaning where the water contains elevated mineral, iron or manganese levels.

INSTALLATION REQUIREMENTS

What Is Required to Install the Puretec HYBRID-G6?

Suitable incoming rainwater or approved water source
Structurally appropriate mounting position
Correct 1" / 25mm plumbing arrangement
Cold-water supply only
Supply pressure within the specified range
Approved pressure limiting above 500kPa
Point-of-entry dual-check backflow protection where required
Suitable isolation valves
AC 240V / 50Hz electrical supply
Suitable surge protection
Adequate service access
Protection from freezing and aggressive environments

The HYBRID-G6 Requires Power

Unlike filtration-only systems such as the Puretec EM2 range, the HYBRID-G6 requires electrical power for its ultraviolet lamp and control system.

Puretec specifies AC 240V / 50Hz power for the Hybrid platform.

Puretec also recommends surge protection and states that the supplied surge-protection device must itself be protected from water and moisture.

Where a suitable power supply is not already available, additional electrical work may be required as part of the overall installation.

Pressure Requirements

Puretec specifies a supply-pressure range of approximately 300–875kPa for the Hybrid system.

Where line pressure exceeds 500kPa, Puretec requires an approved pressure-limiting device.

For rainwater installations, operating pressure also depends on the property's pump performance and plumbing layout.

The pressure available from the pump should therefore be assessed together with the filter and peak household demand.

Backflow Protection at Point of Entry

Puretec's current Hybrid installation guide specifies that an approved dual-check backflow-prevention device must be installed for point-of-entry applications.

The actual installation arrangement needs to comply with applicable plumbing requirements and the property's existing water-source configuration.

Metal Pipe Requirement After the UV Chamber

Puretec's current Hybrid installation instructions specify that the UV chamber should be connected to metal pipe or fittings for at least one metre after the UV outlet.

Plastic pipe or fittings should not be connected directly to the outlet of the UV chamber.

This requirement needs to be allowed for when planning the final pipework layout around the HYBRID-G6.

What's Included With Puretec HYBRID-G6 Installation?

Genuine HYBRID-G6 System

Supply of the current HYBRID-G6-LF with PL05MP1 and DP10MP1 cartridges, RL6 UV lamp, RQS6 quartz sleeve and integrated weather enclosure.

Plumbing Installation

Mounting and connection to suitable existing plumbing, together with flushing, leak checks and commissioning where the existing installation is suitable.

UV Setup

Operational checks of the UV system plus advice on cartridge replacement, lamp replacement and quartz-sleeve maintenance.

Additional bypass plumbing, isolation valves, backflow protection, pressure limiting, rainwater-pump work, mains/rainwater changeover alterations, structural work or electrical work may require additional scope.

How Much Does Puretec HYBRID-G6 Installation Cost?

Current supplied-and-installed pricing is shown through JR's live product and installation options where available.

The final Puretec HYBRID-G6 installation cost depends on existing rainwater plumbing, pump arrangement, water pressure, mounting location, electrical supply, backflow protection, bypass requirements and the amount of pipework alteration needed.

A straightforward installation beside suitable existing plumbing and power is generally simpler than a job requiring pump relocation, new electrical work, mains/rainwater changeover modifications or major pipework changes.

BRISBANE INSTALLATION

Puretec HYBRID-G6 Installation Brisbane

JR Gas & Water supplies and installs the Puretec HYBRID-G6 in Brisbane for suitable whole-house rainwater treatment applications.

The compact dual-filter platform is particularly relevant to small and medium homes wanting more complete rainwater treatment than sediment filtration alone.

JR considers the tank-water source, pump performance, peak household flow, pipe size, water clarity, pressure, electrical supply and servicing access before confirming the final installation arrangement.

Eligible service coverage extends across Greater Brisbane and surrounding areas including Logan, Ipswich, Redlands and Moreton Bay.

GOLD COAST INSTALLATION

Puretec HYBRID-G6 Installation Gold Coast

JR Gas & Water also supplies and installs the Puretec HYBRID-G6 on the Gold Coast across eligible service areas.

For homes using rainwater throughout the property, the G6 provides sediment filtration, carbon treatment and UV treatment before water is distributed through the connected plumbing system.

JR assesses the water source, pump duty, available pressure, pipework, electrical access and future service requirements before commissioning the system.

Can the HYBRID-G6 Replace My Existing Rainwater Filtration System?

Replacing Another G6

A like-for-like replacement may be relatively straightforward where the existing 1-inch plumbing, power supply and mounting position remain suitable.

Upgrading From an EM2

The G6 adds UV treatment to sediment and carbon filtration, introducing electrical and UV servicing requirements.

Replacing Separate Filters + UV

The G6 can consolidate separate filtration and UV equipment into one weather-protected Puretec package where its hydraulic capacity suits the property.

New Rainwater System

A new installation should be designed around tank condition, pump duty, peak household demand, water clarity and required UV dose.

Mains + Rainwater Setup

The Hybrid platform can be used with mains and rainwater, but any mains-to-rainwater changeover system needs to be considered separately.

Poor Water Quality

Additional pre-treatment or water testing may be required where incoming water exceeds Puretec's recommended UV water-quality parameters.

COMMON QUESTIONS

Puretec HYBRID-G6 Installation FAQs

Is the Puretec HYBRID-G6 still a current model?

Yes. Puretec currently maintains a live HYBRID-G6-LF product listing. Puretec also promotes the newer HYBRID-E7 for customers wanting additional capacity and newer features.

What cartridges does the HYBRID-G6 use?

The G6 uses PL05MP1 in Stage 1 and DP10MP1 in Stage 2.

What micron rating is Stage 1?

The PL05MP1 is a nominal 5-micron washable pleated sediment cartridge.

What micron rating is Stage 2?

Puretec lists the DP10MP1 as a nominal 10-micron dual-purpose carbon cartridge.

Does the HYBRID-G6 reduce taste and odour?

Yes. Puretec specifically lists reduction of bad taste, odour and chemicals for the G6 and G7 filtration configuration.

Does the HYBRID-G6 reduce chlorine?

The G6's dual-purpose carbon cartridge provides carbon treatment, and Puretec's G-Series literature includes chlorine among the chemicals reduced by the G6/G7 configuration.

What UV lamp does the G6 use?

The HYBRID-G6 uses the Puretec RL6 46W UV lamp.

What quartz sleeve does the G6 use?

The correct replacement quartz sleeve is the RQS6.

What maintenance kit suits the HYBRID-G6?

Puretec lists the HR-G6R1 maintenance kit for HYBRID-G6 and HYBRID-R1 systems.

What does the HR-G6R1 kit contain?

Puretec lists a PL05MP1 cartridge, DP10MP1 cartridge, RL6 UV lamp, RQS6 quartz sleeve, food-grade lubricant and two replacement O-rings.

What is the maximum G6 flow rate?

Puretec promotes the HYBRID-G6 as a 75 L/min system. UV treatment flow is separately rated according to the UV dose being delivered.

What are the UV flow rates?

Puretec publishes 54 L/min at 40mJ/cm², 70 L/min at 30mJ/cm² and 130 L/min at 16mJ/cm².

Which UV flow applies to drinking water?

Puretec identifies 30mJ/cm² as the industry-standard drinking-water UV dose, corresponding to 70 L/min for the RL6 reactor.

Does the G6 treat E. coli?

Puretec states that its Hybrid UV technology can treat up to 99.99% of E. coli when the system is correctly selected, installed and maintained under suitable water conditions.

Does the G6 treat Giardia and Cryptosporidium?

Puretec specifically includes Giardia and Cryptosporidium cysts among the organisms addressed by the Hybrid UV treatment.

Can the G6 be used on rainwater?

Yes. Rainwater is the G6's primary intended application.

Can the G6 be used on mains water?

Yes. Puretec's Hybrid documentation states that the system is designed for mains and rainwater supply.

Does the HYBRID-G6 require electricity?

Yes. The UV system requires AC 240V / 50Hz power.

Does it require surge protection?

Puretec recommends surge protection for the Hybrid system and supplies a surge-protection device with the unit.

Can the G6 be installed outdoors?

Yes. The G Series includes a weather-protection enclosure intended for suitable outdoor installation.

Does the G6 have a lockable cover?

Yes. Puretec provides an anti-tamper and childproof lockable lid.

Does the UV system have an alarm?

Yes. The Hybrid controller provides visual and audible lamp-failure warnings together with a lamp countdown function.

What pipe connection does the G6 use?

The system uses 1-inch BSP / 25mm connections.

What pressure can the HYBRID-G6 operate at?

Puretec specifies approximately 300–875kPa. Where line pressure exceeds 500kPa, an approved pressure-limiting device is required.

What is the operating temperature range?

Puretec specifies approximately 0°C to 52°C and requires protection from freezing.

Does it need backflow protection?

Puretec's current installation guide specifies an approved dual-check backflow-prevention device for point-of-entry installations.

Why does Puretec require metal pipe after the UV outlet?

Puretec's installation guide specifies metal pipe or fittings for at least one metre after the UV chamber and states that plastic should not be connected directly to the UV outlet.

Why does water clarity matter?

UV light needs to pass through the water effectively. Sediment, staining and other contaminants can reduce UV transmission and compromise treatment performance.

Can Puretec test UV transmission?

Yes. Puretec states that it can arrange a UVT test where customers are unsure whether source-water clarity is suitable for the Hybrid UV system.

What warranty does the HYBRID-G6 have?

Puretec's current warranty schedule places the Hybrid G Series in the 3-year category: one year parts and labour plus two additional years parts only, excluding consumables.

How much does HYBRID-G6 installation cost?

Final cost depends on existing plumbing, rainwater-pump arrangement, electrical supply, pressure control, backflow requirements, mounting position and the amount of additional work required.

Can JR install the Puretec HYBRID-G6 in Brisbane or the Gold Coast?

Yes. JR installs suitable Puretec rainwater filtration and UV systems across eligible Brisbane, Gold Coast and surrounding South East Queensland service areas.

Puretec HYBRID-G6 Warranty

3-Year Puretec Warranty

Puretec's current warranty schedule lists the Hybrid G Series with a 3-year system warranty.

Warranty Structure

The current published structure is 1 year parts and labour plus 2 additional years parts only.

Consumables Excluded

Filter cartridges, UV lamps and other routine service consumables are excluded from the normal system warranty.

Puretec manufacturer warranty and JR installation workmanship warranty are separate. Retain the product documentation supplied with the actual unit for manufacturer warranty claims.

Claims Strengthened or Cleaned Up From the Existing HYBRID-G6 Copy

Confirmed current HYBRID-G6-LF model status
Confirmed dual 10-inch filtration format
Added exact PL05MP1 Stage 1 cartridge
Confirmed Stage 1 is nominal 5 micron
Added exact DP10MP1 Stage 2 cartridge
Confirmed DP10MP1 is nominal 10 micron
Clarified Stage 2 carbon-treatment function
Added exact RL6 46W UV lamp
Added exact RQS6 quartz sleeve
Added HR-G6R1 maintenance kit
Confirmed 75 L/min published G6 system rating
Separated system flow from UV dose/flow figures
Confirmed 54 L/min @ 40mJ/cm²
Confirmed 70 L/min @ 30mJ/cm²
Confirmed 130 L/min @ 16mJ/cm²
Clarified Puretec's 30mJ/cm² drinking-water benchmark
Confirmed 1" BSP / 25mm connections
Confirmed 300–875kPa pressure range
Added pressure-limiting requirement above 500kPa
Confirmed 0–52°C temperature range
Confirmed AC 240V / 50Hz power requirement
Added dual-check backflow requirement for point-of-entry installation
Added Puretec's one-metre metal-pipe requirement after the UV outlet
Added incoming-water quality parameters for UV suitability
Confirmed outdoor weather enclosure
Confirmed lockable lid and UV failure warning
Removed generic claims that cheaper systems are inherently unreliable
Confirmed current 3-year Puretec warranty structure

Why Choose JR Gas & Water for Rainwater Filtration & UV?

JR Gas & Water supplies and installs whole-house rainwater filtration and ultraviolet systems across Brisbane, the Gold Coast and eligible surrounding South East Queensland service areas.

The correct UV system depends on more than its advertised flow rate. Tank-water quality, pump duty, UV transmission, pipe diameter, household demand, pressure, electrical supply, backflow requirements and servicing access all influence the finished installation.

JR assesses the property and water-treatment requirements before confirming whether the HYBRID-G6, another Puretec Hybrid system or a different filtration and UV arrangement is the better fit.

READY TO INSTALL

Install the Puretec HYBRID-G6 With JR Gas & Water

The Puretec HYBRID-G6-LF combines compact dual-stage 10-inch filtration with RL6 ultraviolet treatment inside a weather-protected whole-house rainwater system.

Its strongest fit is small to medium rainwater-fed homes wanting sediment reduction, carbon treatment and microbiological UV treatment in one integrated package.

JR Gas & Water supplies and installs suitable Puretec HYBRID-G6 systems across eligible Brisbane and Gold Coast service areas. Choose the applicable live installation option above, or use JR's quote pathway where the project involves rainwater-pump changes, mains/rainwater changeover, pressure control, backflow work, electrical changes or non-standard water-quality conditions.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.